Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/15347
ชื่อเรื่อง: | Intra-rater and inter-rater reliability of a weight-bearing lunge measure of ankle dorsiflexion |
ผู้แต่ง: | Bennell K. Talbot R. Wajswelner H. Techovanich W. Kelly D. |
Keywords: | adolescent adult ankle article clinical protocol female human human experiment joint mobility male measurement normal human observer variation reliability tibia shaft weight bearing |
วันที่เผยแพร่: | 1998 |
บทคัดย่อ: | This study aimed to evaluate the inter-rater and intra-rater reliability of a weight-bearing dorsiflexion (DF) lunge in 13 healthy subjects. Four raters with varying clinical experience tested all subjects in random order. Two of the raters repeated the measurements one week later. Two methods were used to assess the DF lunge: (i) the distance from the great toe to the wall and (ii) the angle between the tibial shaft and the vertical using an inclinometer. The average of three trials was used in data analysis. Intra-rater intraclass correlation coefficients (ICCs) ranged from 0.97 to 0.98. Inter-rater ICC values were 0.97 (angle) and 0.99 (distance). Results indicate excellent reliability for both methods of assessing a DF lunge. |
URI: | https://ir.swu.ac.th/jspui/handle/123456789/15347 https://www.scopus.com/inward/record.uri?eid=2-s2.0-0031786611&doi=10.1016%2fS0004-9514%2814%2960377-9&partnerID=40&md5=f4bd980e8f4d1877eb546e02c48dab52 |
ISSN: | 49514 |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.