Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/15060
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Karuwan C. | |
dc.contributor.author | Mantim T. | |
dc.contributor.author | Chaisuwan P. | |
dc.contributor.author | Wilairat P. | |
dc.contributor.author | Grudpan K. | |
dc.contributor.author | Jittangprasert P. | |
dc.contributor.author | Einaga Y. | |
dc.contributor.author | Chailapakul O. | |
dc.contributor.author | Suntornsuk L. | |
dc.contributor.author | Anurukvorakun O. | |
dc.contributor.author | Nacapricha D. | |
dc.date.accessioned | 2021-04-05T04:32:26Z | - |
dc.date.available | 2021-04-05T04:32:26Z | - |
dc.date.issued | 2006 | |
dc.identifier.issn | 14243210 | |
dc.identifier.other | 2-s2.0-33947367459 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/15060 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-33947367459&doi=10.3390%2fs6121837&partnerID=40&md5=482d3a4febd812dc93ccff22e3ae48dc | |
dc.description.abstract | This work presents the construction and application of boron-doped diamond (BDD) thin film electrode as sensor for the determination of three β-agonists, viz. salbutamol, terbutaline and clenbuterol. Although well-known as a chemically inert material, BDD film however shows fouling in detection of these compounds using fixed-potential mode amperometry. A suitable waveform for pulsed amperometric detection (PAD) was developed and used to determine the agonist compounds. It was seen that the developed PAD significantly refreshed the BDD surface for long-term detection in flow injection analysis. Linear working ranges were 0.5-100 μM, 1.0-100 μM and 0.5-50 μM for salbutamol, terbutaline and clenbuterol, respectively. The developed PAD-BDD system was applied to successfully determine salbutamol and terbutaline in commercial pharmaceutical products. The methods were validated with a capillary electrophoresis method. © 2006 by MDPI. | |
dc.subject | Capillary electrophoresis | |
dc.subject | Diamonds | |
dc.subject | Boron doped diamond | |
dc.subject | Flow injection | |
dc.subject | Flow injection analysis | |
dc.subject | Pharmaceutical analysis | |
dc.subject | Pharmaceutical products | |
dc.subject | Pulsed amperometric detection | |
dc.subject | Pulsed amperometry | |
dc.subject | Thin-film electrode | |
dc.subject | Boolean functions | |
dc.title | Pulsed amperometry for anti-fouling of boron-doped diamond in electroanalysis of β-agonists: Application to flow injection for pharmaceutical analysis | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | Sensors. Vol 6, No.12 (2006), p.1837-1850 | |
dc.identifier.doi | 10.3390/s6121837 | |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.