Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/15047
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNaphon P.
dc.date.accessioned2021-04-05T04:32:24Z-
dc.date.available2021-04-05T04:32:24Z-
dc.date.issued2006
dc.identifier.issn7351933
dc.identifier.other2-s2.0-32044435825
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/15047-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-32044435825&doi=10.1016%2fj.icheatmasstransfer.2005.09.007&partnerID=40&md5=347e139d8f07c002a60553f566585ed0
dc.description.abstractThe heat transfer characteristics and the pressure drop in the horizontal double pipes with twisted tape insert are investigated. Two test sections with different relative pitches are tested. The inner and outer diameters of the inner tube are 8.10 and 9.54 mm, respectively. The twisted tape is made from the aluminium strip with thickness of 1 mm and the length of 2000 mm. Cold and hot water are used as working fluids in shell side and tube side, respectively. The test runs are done at the cold and hot water mass flow rates ranging between 0.01 and 0.07 kg/s, and between 0.04 and 0.08 kg/s, respectively. The inlet cold and hot water temperatures are between 15 and 20 °C, and between 40 and 45 °C, respectively. The results obtained from the tube with twisted insert are compared with those without twisted tape. Non-isothermal correlations based on the data gathered during this work for predicting the heat transfer coefficient and friction factor of the horizontal pipe with twisted taped insert are proposed. The majority of the data falls within ±15%, ±10% of the proposed correlations for heat transfer coefficient and friction factor, respectively. © 2005 Elsevier Ltd. All rights reserved.
dc.subjectFlow of water
dc.subjectHeat transfer
dc.subjectIntake systems
dc.subjectPressure drop
dc.subjectReynolds number
dc.subjectTemperature control
dc.subjectTribology
dc.subjectTubes (components)
dc.subjectWater heaters
dc.subjectFriction factor
dc.subjectHeat transfer coefficient
dc.subjectHorizontal double pipes
dc.subjectInlet hot water temperatures
dc.subjectTwisted tape insert
dc.subjectWater mass flow
dc.subjectPipe
dc.subjectFlow of water
dc.subjectHeat transfer
dc.subjectIntake systems
dc.subjectPipe
dc.subjectPressure drop
dc.subjectReynolds number
dc.subjectTemperature control
dc.subjectTribology
dc.subjectTubes (components)
dc.subjectWater heaters
dc.titleHeat transfer and pressure drop in the horizontal double pipes with and without twisted tape insert
dc.typeArticle
dc.rights.holderScopus
dc.identifier.bibliograpycitationInternational Communications in Heat and Mass Transfer. Vol 33, No.2 (2006), p.166-175
dc.identifier.doi10.1016/j.icheatmasstransfer.2005.09.007
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.