dc.description.abstractThe results of the heat transfer and pressure drop characteristics in horizontal double pipes with helical ribs are presented. Nine test sections with different characteristic parameters of: helical rib height to diameter, χ/di = 0.12, 0.15, 0.19, and helical rib pitch to diameter, p/di = 1.05, 0.78, 0.63, are tested. Cold and hot water are used as working fluids in the shell side and tube side, respectively. Experiments are performed under conditions of mass flow rates varying from 0.01 to 0.10 kg/s for cold water and from 0.01 to 0.10 kg/s for hot water, respectively. The inlet cold and hot water temperatures are between 15 and 20 °C and between 40 and 50 °C, respectively. The results obtained from the tubes with helical ribs are compared with those without helical ribs. It is found that the helical ribs have a significant effect on the heat transfer and pressure drop augmentations. Based on fitting the experimental data, non-isothermal correlations of the heat transfer coefficient and friction factor are proposed. The majority of the data falls within ±15%, ±15% of the proposed correlations for heat transfer coefficient and friction factor, respectively. © 2006.
dc.subjectData acquisition
dc.subjectHeat pipes
dc.subjectHot water heating
dc.subjectParameter estimation
dc.subjectPressure drop
dc.subjectSuperheater tubes
dc.subjectThermal effects
dc.subjectFriction factor
dc.subjectHeat transfer coefficient
dc.subjectHelical rib
dc.subjectHeat transfer
dc.titleTube side heat transfer coefficient and friction factor characteristics of horizontal tubes with helical rib
dc.typeArticle
dc.rights.holderScopus
dc.identifier.bibliograpycitationEnergy Conversion and Management. Vol 47, No.18-19 (2006), p.3031-3044
dc.identifier.doi10.1016/j.enconman.2006.03.023
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.