Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/14662
ชื่อเรื่อง: | Effect of micro-arc oxidation time on the Ca-P coating layer properties formed on commercially pure titanium |
ผู้แต่ง: | Katekaew P. Veerasai W. Aeimbhu A. |
Keywords: | AFM Atomic force microscopes Ca-P coating Coating layer Commercially Pure titaniums Constant Potential Energy dispersive x-ray spectrometers Mean roughness Micro-porous structure Microarc oxidation Micropores Number and size Oxidation time Roughness SEM SEM micrographs X-ray diffraction techniques XRD Atomic force microscopy Biological materials Biomaterials Biomechanics Biomedical engineering Biophysics Calcium Crystal atomic structure Hydroxyapatite Microporosity Nanofiltration membranes Oxidation Scanning electron microscopy Technical presentations Titanium X ray diffraction Coatings |
วันที่เผยแพร่: | 2010 |
บทคัดย่อ: | In the present study, the Ca-P coating layer on commercially pure titanium was fabricated using Micro-arc oxidation (MAO) method in electrolyte for osteointegrative coating (ESOC) at constant potential for different periods of time (0 - 600 minutes). The morphological microstructures, crystal structure and roughness of Ca-P coating layers were characterised by Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectrometer (EDS), X-ray Diffraction technique (XRD) and Atomic Force Microscope (AFM). SEM micrographs of treated samples demonstrated the microporous structure of Ca-P coating layer. Moreover, the results indicated that the number and size of micropores have increased with an increasing oxidation time. The contents of Ca and P on coating layer depend on the oxidation time. XRD results showed that the fabricated Ca-P coating layer contains Ti and hydroxyapatite (HA) phases at t = 600 minutes. AFM analysis showed that a mean roughness of untreated was 13 nm and treated samples ranging between 80-190 nm. Wettability property of an untreated and treated sample was hydrophilic which the magnitude was no different. © 2010 International Federation for Medical and Biological Engineering. |
URI: | https://ir.swu.ac.th/jspui/handle/123456789/14662 https://www.scopus.com/inward/record.uri?eid=2-s2.0-77958010844&doi=10.1007%2f978-3-642-14515-5_304&partnerID=40&md5=866cee0138c489da2120956aac69775d |
ISSN: | 16800737 |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.