Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/14568
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Naphon P. | |
dc.date.accessioned | 2021-04-05T03:35:37Z | - |
dc.date.available | 2021-04-05T03:35:37Z | - |
dc.date.issued | 2011 | |
dc.identifier.issn | 7351933 | |
dc.identifier.other | 2-s2.0-79451475775 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/14568 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-79451475775&doi=10.1016%2fj.icheatmasstransfer.2010.11.016&partnerID=40&md5=ae4e891dcd42bc9719989d16a1c95905 | |
dc.description.abstract | Experimental and theoretical investigations on the entropy generation, exergy loss of a horizontal concentric micro-fin tube heat exchanger are presented. The experiments setup are designed and constructed for the measured data by using hot water and cold water as working fluids. The micro-fin tube is fabricated from the copper tube with an inner diameter of 8.92. mm. The experiments are performed for the hot and cold water mass flow rates in the range of 0.02-0.10. kg/s. The inlet hot water and inlet cold water temperatures are between 40 and 50 °C, and between 15 and 20 °C, respectively. The effects of relevant parameters on the entropy generation, and exergy loss are discussed. A central finite difference method is employed to solve the model for obtaining temperature distribution, entropy generation, and exergy loss of the micro-fin tube heat exchanger. The predicted results obtained from the model are verified by comparing with the present measured data. Reasonable agreement is obtained from the comparison between predicted results and those from the measured data. © 2010 Elsevier Ltd. | |
dc.subject | Central finite difference | |
dc.subject | Cold waters | |
dc.subject | Copper tubes | |
dc.subject | Entropy generation | |
dc.subject | Exergy loss | |
dc.subject | Hot water | |
dc.subject | Inner diameters | |
dc.subject | Measured data | |
dc.subject | Micro-fin tube | |
dc.subject | Theoretical investigations | |
dc.subject | Working fluid | |
dc.subject | Cold working | |
dc.subject | Exergy | |
dc.subject | Experiments | |
dc.subject | Fins (heat exchange) | |
dc.subject | Heat exchangers | |
dc.subject | Hot working | |
dc.subject | Tubes (components) | |
dc.subject | Water | |
dc.subject | Entropy | |
dc.title | Study on the exergy loss of the horizontal concentric micro-fin tube heat exchanger | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | International Communications in Heat and Mass Transfer. Vol 38, No.2 (2011), p.229-235 | |
dc.identifier.doi | 10.1016/j.icheatmasstransfer.2010.11.016 | |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.