Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/14183
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSaetear P.
dc.contributor.authorKhamtau K.
dc.contributor.authorRatanawimarnwong N.
dc.contributor.authorSereenonchai K.
dc.contributor.authorNacapricha D.
dc.date.accessioned2021-04-05T03:33:29Z-
dc.date.available2021-04-05T03:33:29Z-
dc.date.issued2013
dc.identifier.issn399140
dc.identifier.other2-s2.0-84879108107
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/14183-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84879108107&doi=10.1016%2fj.talanta.2013.05.051&partnerID=40&md5=2caf8c280866bd16b94f91ba97d0d190
dc.description.abstractThis work presents the simultaneous determination of sucrose and phosphate by using sequential injection (SI) system with a low cost paired emitter-detector diode (PEDD) light sensor. The PEDD uses two 890 nm LEDs. Measurement of sucrose in Brix unit was carried out based on the detection of light refraction occurring at the liquid interface (the schlieren effect) between the sucrose solution and water. Phosphate was measured from the formation of calcium phosphate with turbidimetric detection. With careful design of the loading sequence and volume (sample - precipitating reagent - sample), simultaneous detection of sucrose and phosphate was accomplished with the single PEDD detector. At the optimized condition, linear calibrations from 1 to 7 Brix sucrose and from 50 to 200 mg PO43- L-1 were obtained. Good precision at lower than 2% RSD (n=10) for both analytes with satisfactory throughput of 21 injections h-1 was achieved. The method was successfully applied for the determination of sucrose and phosphate in cola drinks. The proposed method is readily applicable for automation and is found to be an alternative method to conventional procedures for on-line quality control process in cola drink industry. © 2013 Published by Elsevier B.V.All rights reserved.
dc.subjectBeverages
dc.subjectCalcium phosphate
dc.subjectDiodes
dc.subjectPhase interfaces
dc.subjectPhosphates
dc.subjectCola drinks
dc.subjectOn-line quality control
dc.subjectPaired emitter detector diodes
dc.subjectSchlieren effects
dc.subjectSequential injection systems
dc.subjectSimultaneous detection
dc.subjectSimultaneous determinations
dc.subjectTurbidimetry
dc.subjectSugar (sucrose)
dc.titleSequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitter-detector diode sensor
dc.typeArticle
dc.rights.holderScopus
dc.identifier.bibliograpycitationTalanta. Vol 115, No. (2013), p.361-366
dc.identifier.doi10.1016/j.talanta.2013.05.051
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.