ชื่อเรื่อง: New membraneless vaporization unit coupled with flow systems for analysis of ethanol
ผู้แต่ง: Ratanawimarnwong N.
Pluangklang T.
Chysiri T.
Nacapricha D.
Keywords: Chromatographic methods
Dual chamber
Gas diffusion process
Membraneless vaporization units
Oxidation reactions
Percentage recovery
Potassium dichromates
Volatile compounds
Chromatographic analysis
Vaporization
Vapors
Volatile organic compounds
Ethanol
alcohol
dichromate potassium
volatile agent
accuracy
article
chemical analysis
chemical composition
controlled study
diffusion
equipment design
gas chromatography
measurement
membraneless vaporization
oxidation
priority journal
quantitative analysis
reliability
vaporization
volumetry
วันที่เผยแพร่: 2013
บทคัดย่อ: This work presents the development of a new design for a membraneless vaporization (MBL-VP) unit, called dual chamber MBL-VP for measurement of volatile compounds. With this unit, exact volumes of sample and reagent are introduced into their respective cone-shaped chambers from the base of the cones. Diffusion of volatile analyte then takes place. After an appropriate time interval, the acceptor solution is withdrawn from the chamber into the detector flow-cell, while the sample solution is withdrawn to waste. Unlike the previous MBL-VP design, problems with overflow of solutions are eliminated by precise control of the input volume to be less than the volume of the chamber. The developed flow system with the dual chamber MBL-VP unit was applied to the determination of the ethanol content of various liquid samples, using the oxidation reaction between potassium dichromate and the diffused ethanol. In addition, in order to accelerate the gas diffusion process, the donor chamber was aerated. As the result, relatively short analysis time of 144. s was achieved for ethanol content in the range of 5-50% (v/v). The proposed method was successfully validated against a gas chromatographic method for 17 alcoholic samples. Percentage recovery was in the range of 96-109%. © 2013 Elsevier B.V.
URI: https://ir.swu.ac.th/jspui/handle/123456789/13994
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84883561185&doi=10.1016%2fj.aca.2013.07.072&partnerID=40&md5=7f11a3ccd42ccbb1bfaf513680a36782
ISSN: 32670
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.