Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/13945
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSenavongse W.
dc.contributor.authorDron N.
dc.contributor.authorPrakopkaew P.
dc.contributor.authorTammawong W.
dc.date.accessioned2021-04-05T03:32:44Z-
dc.date.available2021-04-05T03:32:44Z-
dc.date.issued2013
dc.identifier.other2-s2.0-84893270387
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/13945-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84893270387&doi=10.1109%2fBMEiCon.2013.6687646&partnerID=40&md5=54bb05ba995da2d94f398438e7974deb
dc.description.abstractStroke patient rehabilitation by treadmill tends to increase in recent years. The rehabilitation on treadmill needs more than two staffs per patient to control the process and protect them from falling. As a result, it takes too much time and resource to operate. To resolve this problem, this paper proposes to develop an automatic sensor that is simple and easy to use by using ultrasonic sensor and the Arduino board. The system senses patient's body on treadmill to calculate the suitable distance for setting an automatic switch. When patient' body triggers the first position, the treadmill will start moving then patient's body triggers the second distance or fall position, the treadmill will stop immediately. Although it is a simple concept, the commercial treadmill does not have this function which is necessary for looking after patients. The control system uses Arduino and C# languages. The findings suggest that the performance of the system is very satisfactory having accuracy which are measured in 2 states, on and off, at 94.32% and 94.83% respectively. © 2013 IEEE.
dc.subjectFall detection
dc.subjectstroke
dc.subjectwalking
dc.subjectBiomedical engineering
dc.subjectExercise equipment
dc.subjectSensors
dc.subjectSporting goods
dc.subjectUltrasonic applications
dc.subjectUltrasonics
dc.subjectPatient rehabilitation
dc.titleAutomatic fall detection sensor for treadmill rehabilitation
dc.typeConference Paper
dc.rights.holderScopus
dc.identifier.bibliograpycitationBMEiCON 2013 - 6th Biomedical Engineering International Conference. (2013)
dc.identifier.doi10.1109/BMEiCon.2013.6687646
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.