Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/13861
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLekskulchai V.
dc.date.accessioned2021-04-05T03:32:31Z-
dc.date.available2021-04-05T03:32:31Z-
dc.date.issued2014
dc.identifier.issn450618
dc.identifier.other2-s2.0-84907590228
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/13861-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84907590228&doi=10.1080%2f00450618.2014.891653&partnerID=40&md5=c53269d5a4bbc236d0a7718df68c17cc
dc.description.abstractIn forensic cases, blood alcohol is routinely requested. Although the standard method for alcohol analysis is the gas chromatographic technique, the instrument is not available in some hospital laboratories. As a result, there is an attempt to use an automatic alcohol analyzer for preliminary testing. However, a barrier to application is the putrefactive changes of post-mortem specimens that might interfere with the analysis and cause false positive results. This study aims to determine the accuracy of an automatic VITROS alcohol analysis for post-mortem specimens. Blood and urine samples were modified to putrefactive appearances and analyzed for ethanol by VITROS. The measured amounts were compared with the added ethanol amounts. The results indicated that samples with fresh hemolysis and putrefactive volatile substances gave false high ethanol results. Plasma with a high glucose content in the presence of Escherichia coli or Candida albicans did not show neo-ethanol formation. Indeed, all samples left at room temperature prior to analysis showed false low detected ethanol amounts. Thus, VITROS alcohol analysis has limitations leading to inaccurate post-mortem specimen analysis. In addition, loss of alcohol from corpses and specimen containers also has an impact on the accuracy of alcohol results in post-mortem cases. © 2014 Australian Academy of Forensic Sciences.
dc.subject2 propanol
dc.subjectalcohol
dc.subjectbutanol
dc.subjectglucose
dc.subjectmethanol
dc.subjectpropanol
dc.subjectaccuracy
dc.subjectalcohol blood level
dc.subjectArticle
dc.subjectautopsy
dc.subjectCandida albicans
dc.subjectcontainer
dc.subjectEscherichia coli
dc.subjectfalse positive result
dc.subjectglucose blood level
dc.subjectglucose urine level
dc.subjecthemolysis
dc.subjectroom temperature
dc.subjecturinalysis
dc.titleAccuracy of VITROS alcohol analysis for post-mortem specimens
dc.typeArticle
dc.rights.holderScopus
dc.identifier.bibliograpycitationAustralian Journal of Forensic Sciences. Vol 46, No.4 (2014), p.433-441
dc.identifier.doi10.1080/00450618.2014.891653
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.