Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/13718
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chaisuwan P. | |
dc.contributor.author | Moonta T. | |
dc.contributor.author | Sangcakul A. | |
dc.contributor.author | Nacapricha D. | |
dc.contributor.author | Wilairat P. | |
dc.contributor.author | Uraisin K. | |
dc.date.accessioned | 2021-04-05T03:25:56Z | - |
dc.date.available | 2021-04-05T03:25:56Z | - |
dc.date.issued | 2015 | |
dc.identifier.issn | 16159306 | |
dc.identifier.other | 2-s2.0-84925349843 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/13718 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84925349843&doi=10.1002%2fjssc.201401101&partnerID=40&md5=b8648405c70a539399172c111f4e8f4b | |
dc.description.abstract | An in-house flow-injection capillary electrophoresis with capacitively coupled contactless conductivity detection method was developed for the direct measurement of colistin in pharmaceutical samples. The flow injection and capillary electrophoresis systems are connected by an acrylic interface. Capillary electrophoresis separation is achieved within 2 min using a background electrolyte solution of 5 mM 2-morpholinoethanesulfonic acid and 5 mM histidine (pH 6). The flow-injection section allows for convenient filling of the capillary and sample introduction without the use of a pressure/vacuum manifold. Capacitively coupled contactless conductivity detection is employed since colistin has no chromophore but is cationic at pH 6. Calibration curve is linear from 20 to 150 mg/L, with a correlation coefficient (r2) of 0.997. The limit of quantitation is 20 mg/L. The developed method provides precision, simplicity, and short analysis time. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. | |
dc.subject | Amino acids | |
dc.subject | Chromophores | |
dc.subject | Back ground electrolyte | |
dc.subject | Capacitively coupled contactless conductivity detection | |
dc.subject | Capillary electrophoresis separation | |
dc.subject | Colistin | |
dc.subject | Correlation coefficient | |
dc.subject | Flow injection | |
dc.subject | Limit of quantitations | |
dc.subject | Polymyxin E | |
dc.subject | Capillary electrophoresis | |
dc.subject | 2 morpholinoethanesulfonic acid | |
dc.subject | amino acid | |
dc.subject | colistin | |
dc.subject | histidine | |
dc.subject | unclassified drug | |
dc.subject | antiinfective agent | |
dc.subject | colistin | |
dc.subject | Article | |
dc.subject | capillary electrophoresis | |
dc.subject | chromatophore | |
dc.subject | conductance | |
dc.subject | drug determination | |
dc.subject | flow injection capillary electrophoresis | |
dc.subject | hydrodynamics | |
dc.subject | limit of quantitation | |
dc.subject | membrane filter | |
dc.subject | pH | |
dc.subject | priority journal | |
dc.subject | capillary electrophoresis | |
dc.subject | devices | |
dc.subject | evaluation study | |
dc.subject | flow injection analysis | |
dc.subject | procedures | |
dc.subject | Anti-Bacterial Agents | |
dc.subject | Colistin | |
dc.subject | Electrophoresis, Capillary | |
dc.subject | Flow Injection Analysis | |
dc.title | Simple in-house flow-injection capillary electrophoresis with capacitively coupled contactless conductivity method for the determination of colistin | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | Journal of Separation Science. Vol 38, No.6 (2015), p.1035-1041 | |
dc.identifier.doi | 10.1002/jssc.201401101 | |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.