Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/13689
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChiradeja P.
dc.contributor.authorNgaopitakkul A.
dc.contributor.authorJettanasen C.
dc.date.accessioned2021-04-05T03:25:44Z-
dc.date.available2021-04-05T03:25:44Z-
dc.date.issued2015
dc.identifier.issn3787788
dc.identifier.other2-s2.0-84927718027
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/13689-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84927718027&doi=10.1016%2fj.enbuild.2015.03.042&partnerID=40&md5=a295f1fdc9f747c1726b9c422256b594
dc.description.abstractLighting is one of the major energy end uses, which accounts for approximately 20-30% of electricity consumption in buildings. In fact, the fluorescent lamp is the most employed lamp in a lighting system for both inside and outside the building. The ballast is one of the major components of fluorescent lamps; it exists commercially as an electromagnetic ballast, a low loss ballast and an electronic ballast. To reduce energy consumption in a lighting system, the electronic ballast has already been introduced for profit in terms of its peak demand reduction and energy conservation in the building. However, when the electronic ballast functions, harmonics will be generated. Hence, this paper investigates energy savings and the generation of harmonics when using a fluorescent T5 lamp with electronic ballast in a building. The efficiency indices in terms of illumination, energy savings, and harmonics are also evaluated and compared with the fluorescent T8 lamp operating with a low watt loss electromagnetic ballast, which is also widely used. The obtained results are useful for the design and decision to install a fluorescent T5 lamp with electronic ballast in building lighting system to conserve energy and/or reduce energy consumption for the future of the country. © 2015 Published by Elsevier B.V.
dc.subjectBallasts (lamp)
dc.subjectBuildings
dc.subjectEnergy utilization
dc.subjectFluorescence
dc.subjectFluorescent lamps
dc.subjectHarmonic analysis
dc.subjectHistoric preservation
dc.subjectLighting
dc.subjectLighting fixtures
dc.subjectElectricity-consumption
dc.subjectElectromagnetic ballasts
dc.subjectElectronic ballasts
dc.subjectGeneration of harmonics
dc.subjectHarmonics
dc.subjectHarmonics reduction
dc.subjectLighting systems
dc.subjectReduce energy consumption
dc.subjectEnergy conservation
dc.titleEnergy savings analysis and harmonics reduction for the electronic ballast of T5 fluorescent lamp in a building's lighting system
dc.typeArticle
dc.rights.holderScopus
dc.identifier.bibliograpycitationEnergy and Buildings. Vol 97, (2015), p.107-117
dc.identifier.doi10.1016/j.enbuild.2015.03.042
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.