DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nantaphol S. | |
dc.contributor.author | Chailapakul O. | |
dc.contributor.author | Siangproh W. | |
dc.date.accessioned | 2021-04-05T03:25:31Z | - |
dc.date.available | 2021-04-05T03:25:31Z | - |
dc.date.issued | 2015 | |
dc.identifier.issn | 32670 | |
dc.identifier.other | 2-s2.0-84941874160 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/13669 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84941874160&doi=10.1016%2fj.aca.2015.08.007&partnerID=40&md5=7849373478273ee7e8f0c829b121d56b | |
dc.description.abstract | A novel paper-based analytical device (PAD) coupled with a silver nanoparticle-modified boron-doped diamond (AgNP/BDD) electrode was first developed as a cholesterol sensor. The AgNP/BDD electrode was used as working electrode after modification by AgNPs using an electrodeposition method. Wax printing was used to define the hydrophilic and hydrophobic areas on filter paper, and then counter and reference electrodes were fabricated on the hydrophilic area by screen-printing in house. For the amperometric detection, cholesterol and cholesterol oxidase (ChOx) were directly drop-cast onto the hydrophilic area, and H2O2 produced from the enzymatic reaction was monitored. The fabricated device demonstrated a good linearity (0.39 mg dL-1 to 270.69 mg dL-1), low detection limit (0.25 mg dL-1), and high sensitivity (49.61 μA mM-1 cm-2). The precision value for ten replicates was 3.76% RSD for 1 mM H2O2. In addition, this biosensor exhibited very high selectivity for cholesterol detection and excellent recoveries for bovine serum analysis (in the range of 99.6-100.8%). The results showed that this new sensing platform will be an alternative tool for cholesterol detection in routine diagnosis and offers the advantages of low sample/reagent consumption, low cost, portability, and short analysis time. © 2015 Elsevier B.V. | |
dc.subject | Analytic equipment | |
dc.subject | Chemical detection | |
dc.subject | Cholesterol | |
dc.subject | Diamonds | |
dc.subject | Electrodes | |
dc.subject | Hydrophilicity | |
dc.subject | Metal nanoparticles | |
dc.subject | Nanoparticles | |
dc.subject | Paper | |
dc.subject | Screen printing | |
dc.subject | Silver | |
dc.subject | Amperometric detection | |
dc.subject | Boron doped diamond electrodes | |
dc.subject | ELectrochemical detection | |
dc.subject | Electrodeposition methods | |
dc.subject | Hydrophilic and hydrophobic | |
dc.subject | Paper based devices | |
dc.subject | Paper-based analytical devices | |
dc.subject | Silver nanoparticles | |
dc.subject | Electrochemical electrodes | |
dc.subject | boron | |
dc.subject | cholesterol | |
dc.subject | cholesterol oxidase | |
dc.subject | diamond | |
dc.subject | hydrogen peroxide | |
dc.subject | silver nanoparticle | |
dc.subject | boron | |
dc.subject | cholesterol | |
dc.subject | diamond | |
dc.subject | metal nanoparticle | |
dc.subject | silver | |
dc.subject | adult | |
dc.subject | amperometry | |
dc.subject | analytical equipment | |
dc.subject | Article | |
dc.subject | biosensor | |
dc.subject | bovine | |
dc.subject | chemical modification | |
dc.subject | chemical phenomena | |
dc.subject | cholesterol blood level | |
dc.subject | controlled study | |
dc.subject | cost control | |
dc.subject | electrochemical detection | |
dc.subject | electrode | |
dc.subject | electrodeposition | |
dc.subject | filter paper | |
dc.subject | hydrophilicity | |
dc.subject | hydrophobicity | |
dc.subject | limit of detection | |
dc.subject | lipid analysis | |
dc.subject | measurement precision | |
dc.subject | nanofabrication | |
dc.subject | nonhuman | |
dc.subject | paper based analytical device | |
dc.subject | portable equipment | |
dc.subject | printing | |
dc.subject | priority journal | |
dc.subject | reaction time | |
dc.subject | screen printing | |
dc.subject | sensitivity analysis | |
dc.subject | animal | |
dc.subject | blood | |
dc.subject | chemistry | |
dc.subject | devices | |
dc.subject | electrochemical analysis | |
dc.subject | electrode | |
dc.subject | equipment design | |
dc.subject | evaluation study | |
dc.subject | genetic procedures | |
dc.subject | paper | |
dc.subject | Animals | |
dc.subject | Biosensing Techniques | |
dc.subject | Boron | |
dc.subject | Cattle | |
dc.subject | Cholesterol | |
dc.subject | Diamond | |
dc.subject | Electrochemical Techniques | |
dc.subject | Electrodes | |
dc.subject | Equipment Design | |
dc.subject | Limit of Detection | |
dc.subject | Metal Nanoparticles | |
dc.subject | Paper | |
dc.subject | Silver | |
dc.title | A novel paper-based device coupled with a silver nanoparticle-modified boron-doped diamond electrode for cholesterol detection | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | Analytica Chimica Acta. Vol 891, (2015), p.136-143 | |
dc.identifier.doi | 10.1016/j.aca.2015.08.007 | |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.