Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/13221
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jampasa S. | |
dc.contributor.author | Siangproh W. | |
dc.contributor.author | Laocharoensuk R. | |
dc.contributor.author | Vilaivan T. | |
dc.contributor.author | Chailapakul O. | |
dc.date.accessioned | 2021-04-05T03:22:46Z | - |
dc.date.available | 2021-04-05T03:22:46Z | - |
dc.date.issued | 2018 | |
dc.identifier.issn | 399140 | |
dc.identifier.other | 2-s2.0-85042707817 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/13221 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85042707817&doi=10.1016%2fj.talanta.2018.02.075&partnerID=40&md5=1da3da462cb55f542acd0fa03c80ed06 | |
dc.description.abstract | In this present work, a novel electrochemical immunosensor employing a screen-printed graphene electrode (SPGE) for a simple and highly sensitive determination of C-reactive protein (CRP) in a sandwich-type format was proposed. The sensor comprised of two CRP-specific antibodies: an unlabeled capture primary antibody (Anti-1°Ab) and an electrochemically detectable anthraquinone-labeled signaling secondary (AQ-2°Ab) antibody. The Anti-1°Ab was first covalently anchored onto an L-cysteine/gold-modified disposable SPGE (L-Cys/Au/SPGE) to create the anti-CRP surface. After binding of the CRP and the AQ-2°Ab, the electrochemical signal response was measured using differential pulse voltammetry (DPV). In the presence of CRP, the sensor exhibited a significant increase in the AQ current at AQ-2°Ab compared to the negative control. The CRP concentration was detected in the range of 0.01–150 µg/mL, and the limit of detection (LOD) (S/N = 3) and limit of quantitation (LOQ) (10 SD/Slope) were 1.5 ng/mL and 10 ng/mL, respectively. This sensor exhibited very high sensitivity in determining CRP and was successfully applied to detect CRP in certified human serum with satisfactory results. The developed sensor is suitable as an alternative method for determination of CRP and the same principle may be further applied to determine other clinically important target molecules. © 2018 Elsevier B.V. | |
dc.subject | Amino acids | |
dc.subject | Antibodies | |
dc.subject | Aromatic compounds | |
dc.subject | Electrochemical electrodes | |
dc.subject | Electrochemical sensors | |
dc.subject | Graphene | |
dc.subject | Graphite electrodes | |
dc.subject | Ketones | |
dc.subject | Molecules | |
dc.subject | Voltammetry | |
dc.subject | Anthraquinone | |
dc.subject | C-reactive proteins | |
dc.subject | Differential pulse voltammetry | |
dc.subject | ELectrochemical detection | |
dc.subject | Electrochemical immunosensors | |
dc.subject | Electrochemical signals | |
dc.subject | Sandwich format | |
dc.subject | Screen-printed graphene electrodes | |
dc.subject | Chemical detection | |
dc.subject | anthraquinone derivative | |
dc.subject | antibody | |
dc.subject | C reactive protein | |
dc.subject | graphite | |
dc.subject | chemistry | |
dc.subject | electrochemical analysis | |
dc.subject | electrode | |
dc.subject | genetic procedures | |
dc.subject | human | |
dc.subject | printing | |
dc.subject | Anthraquinones | |
dc.subject | Antibodies | |
dc.subject | Biosensing Techniques | |
dc.subject | C-Reactive Protein | |
dc.subject | Electrochemical Techniques | |
dc.subject | Electrodes | |
dc.subject | Graphite | |
dc.subject | Humans | |
dc.subject | Printing | |
dc.title | Electrochemical detection of c-reactive protein based on anthraquinone-labeled antibody using a screen-printed graphene electrode | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | Talanta. Vol 183, (2018), p.311-319 | |
dc.identifier.doi | 10.1016/j.talanta.2018.02.075 | |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.