Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/12750
Title: Temperature-dependent schlieren effect in liquid flow for chemical analysis
Authors: Suwanrut J.
Chantipmanee N.
Kamsong W.
Buking S.
Mantim T.
Saetear P.
Nacapricha D.
Keywords: Ascorbic acid
Chromates
Deionized water
Ethanol
Heat exchangers
Liquids
Refractive index
Analyte concentration
Concentration-dependent
Exothermic oxidation
Flow injection analysis
Schlieren effects
Temperature dependent
Temperature differences
Thermal sensing
Chemical analysis
Issue Date: 2018
Abstract: In flow analysis, such as flow injection analysis, liquid lens is formed at the boundary between two adjacent liquid media which have different refractive indices. Light refraction at the liquid interface gives the so-called 'schlieren signal’. Schlieren effect is both concentration-dependent and temperature-dependent. In this work, the schlieren signal from temperature difference was quantitatively investigated for application in enthalpimetric measurement. The schlieren phenomena was then exploited for chemical analysis. A thermal insulated single flow line manifold was constructed using deionized water at 23 °C as the carrier. Deionized water at various temperatures in the range of 5–85 °C was injected into the carrier flow. A correlation between the schlieren signal and sample temperature was observed. A heat exchanger unit (HEU), consisting of a small volume glass-reaction chamber with a surrounding water jacket, was constructed. The unit was thermally insulated in a double layer cylindrical PVC unit. For demonstrating the applicability of temperature-dependent schlieren effect in chemical analysis, the exothermic oxidation reaction between acid dichromate and ethanol or ascorbic acid was employed with heat transferring to the surrounding water layer. When an aliquot of water from the HEU is injected into the constant temperature flow line the observed schlieren signal was dependent on the analyte concentration. Linear calibration (r2 > 0.99) were obtained covering the concentration range of ethanol and ascorbic acid as found in samples. The developed flow system provides good precision (RSD < 5%) with sample throughput of 4 sample h−1. The system were applied to the determination of ethanol in Thai white spirit and ascorbic acid in vitamin C tablets, respectively. The quantitative results obtained from the schlieren method were in agreement with the comparative methods. © 2018 Elsevier B.V.
URI: https://ir.swu.ac.th/jspui/handle/123456789/12750
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85047274682&doi=10.1016%2fj.talanta.2018.05.055&partnerID=40&md5=c3c546ca9c98285f4142440e09af7977
ISSN: 399140
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.