Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/12528
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jaysrichai T. | |
dc.contributor.author | Srikongphan K. | |
dc.contributor.author | Jurarakpong P. | |
dc.date.accessioned | 2021-04-05T03:03:58Z | - |
dc.date.available | 2021-04-05T03:03:58Z | - |
dc.date.issued | 2019 | |
dc.identifier.issn | 18741207 | |
dc.identifier.other | 2-s2.0-85079529435 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/12528 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079529435&doi=10.2174%2f1874120701913010151&partnerID=40&md5=6cd1b117ea0f55600dea8c419396d171 | |
dc.description.abstract | Objective: To develop and evaluate the device for measuring precision (in percentage) and response time (in seconds) of punches. Methods: Researchers cooperated with Sports Authority of Thailand and the Amateur Boxing Association of Thailand in development. Results: Robo-Boxing Trainer machine consisted of four targets. Each punching target has eight sensors and eight LED lights. Operating software, which programmed by PLC-CX programmer and DOPSoft (delta), can set the punching series and alarm signals. It recorded the response time from the starting signal to making contact with the target, calculating precision in percentage. This software could be set and recorded maximal 40 series and maximal 100 punches in each punching series. Researchers compared the accuracy of counting time with Digital Oscilloscope and tested the efficiency of sensors’ cutting signal. This study found the counting time to be of high accuracy (100% and 98.8%). The cutting sensors' signal test found to be efficient. Conclusion: Robo-Boxing Trainer machine, which is high in accuracy, may help to test and improve a boxer’s skills. Also, it can apply to train for other related sports. © 2019 Jaysrichai et al. | |
dc.subject | Article | |
dc.subject | boxer | |
dc.subject | boxing | |
dc.subject | force | |
dc.subject | machine | |
dc.subject | reaction time | |
dc.subject | robotics | |
dc.subject | software | |
dc.subject | Thailand | |
dc.title | A development machine for measuring the precision and the response time of punches | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | Open Biomedical Engineering Journal. Vol 13, No.1 (2019), p.151-157 | |
dc.identifier.doi | 10.2174/1874120701913010151 | |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.