Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/12511
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLasomsri P.
dc.contributor.authorYanbuaban P.
dc.contributor.authorKerdpoca O.
dc.contributor.authorOuypornkochagorn T.
dc.date.accessioned2021-04-05T03:03:54Z-
dc.date.available2021-04-05T03:03:54Z-
dc.date.issued2019
dc.identifier.other2-s2.0-85062214639
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/12511-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85062214639&doi=10.1109%2fECTICon.2018.8619934&partnerID=40&md5=8c210690f05dfb829a7cda0eeb589fbd
dc.description.abstractPoor Indoor Air Quality (IAQ) is an issue of environmental health problems that cause headaches, fatigue, irritation of the eyes and skin. IAQ in hospital areas is a serious concern since there are many occupants i.e. patients, medical practitioners, and staffs. Furthermore, medical material, medicine, medical gases can cause the quality of air deteriorate. IAQ then requires to regularly check the service areas in order to maintain a good level of air quality. The instrument to measure IAQ is usually expensive. In this study, a low-cost device to measure IAQ was developed, it comprises of two main sensors: BME680 and CCS811. The device was capable of measuring and recording continuously which allows it to monitor air quality including Total Volatile Organic Compounds (TVOC), temperature and humidity. The device was employed to measure three service areas of a large-scale hospital in Nakhonnayok, Thailand: the waiting area, the emergency room, and the outpatient pharmacy. IAQs of these areas obtained from the developed device were all in the very bad level. It is possibly due to the influence of structural renovation, medical material, air conditioning, air ventilation, and the people occupied in the areas. © 2018 IEEE
dc.subjectAir conditioning
dc.subjectAir quality
dc.subjectCosts
dc.subjectHospitals
dc.subjectMedicine
dc.subjectVolatile organic compounds
dc.subjectAir ventilation
dc.subjectEnvironmental health
dc.subjectIndoor air quality
dc.subjectLow-cost devices
dc.subjectMedical materials
dc.subjectMedical practitioner
dc.subjectTemperature and humidities
dc.subjectTotal volatile organic compounds
dc.subjectIndoor air pollution
dc.titleA development of low-cost devices for monitoring indoor air quality in a large-scale hospital
dc.typeConference Paper
dc.rights.holderScopus
dc.identifier.bibliograpycitationECTI-CON 2018 - 15th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology. (2019), p.282-285
dc.identifier.doi10.1109/ECTICon.2018.8619934
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.