Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/12174
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChantipmanee N.
dc.contributor.authorSonsa-ard T.
dc.contributor.authorFukana N.
dc.contributor.authorKotakanok K.
dc.contributor.authorMantim T.
dc.contributor.authorWilairat P.
dc.contributor.authorHauser P.C.
dc.contributor.authorNacapricha D.
dc.date.accessioned2021-04-05T03:02:05Z-
dc.date.available2021-04-05T03:02:05Z-
dc.date.issued2020
dc.identifier.issn399140
dc.identifier.other2-s2.0-85070643037
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/12174-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85070643037&doi=10.1016%2fj.talanta.2019.120227&partnerID=40&md5=affb4d730d29f395134ef0126f392280
dc.description.abstractThis work presents a capacitively coupled contactless conductivity detector (C4D) etched out from a printed circuit board (PCB) as potential sensor for paper-based analytical systems. Two lines of any desirable pattern forming 35-μm thick planar copper electrodes were produced on a PCB plate (40 mm × 60 mm) by photolithography. The final PCB plate was covered with polypropylene film to serve as the insulating layer for the C4D detector. The film also protected the copper electrodes from corrosion. Electrodes made in this planar geometry make the PCB-C4D suitable as sensor for flat devices such as paper-based analytical devices. For this work, plain paper strips were employed as sample reservoir and as fluidic channel without hydrophobic pattern. A dried paper strip was first placed over the sensor, followed by dispensing a fixed volume of the liquid sample onto the paper. Entrapment of the liquid sample in the paper strip leads to reproducible size and position of the detection zone of the sample liquid for the capacitive coupling effect. High precision was obtained with %RSD ≤1% (n = 18) for standard solutions of KCl. Soil suspensions could be analyzed without prior filtration by placing a drop onto the paper strip extending away from the detector zone. The paper strip filtered out soil particles at the surface of the paper. Therefore, only soil filtrate moved towards the detection zone by lateral flow. The C4D detection using paper strip showed high tolerance to soil suspension with turbidity up to 6657 NTU, offering direct analysis of soil salinity. Cleaning with moist tissue paper between samples is adequate even for dirty samples such as soil suspension. We also monitored conductivity of acid-base reaction in the microfluidic paper channels, which was later applied to the quantification of bicarbonate in water and in antacid tablet (“Soda Mint Tablet”). © 2019 Elsevier B.V.
dc.subjectAnalytic equipment
dc.subjectCarbonates
dc.subjectCopper corrosion
dc.subjectCorrosion protection
dc.subjectElectrodes
dc.subjectFiltration
dc.subjectGeometry
dc.subjectLiquids
dc.subjectParticle size analysis
dc.subjectPlastic films
dc.subjectPolypropylenes
dc.subjectPotassium compounds
dc.subjectSensors
dc.subjectSoils
dc.subjectTiming circuits
dc.subjectCapacitive coupling effects
dc.subjectCapacitively coupled
dc.subjectContactless conductivity detector
dc.subjectHydrophobic patterns
dc.subjectPaper-based analytical devices
dc.subjectPoly-propylene film
dc.subjectPrinted circuit boards (PCB)
dc.subjectSoil salinity
dc.subjectPrinted circuit boards
dc.subjectCarbonates
dc.subjectCorrosion Prevention
dc.subjectElectrodes
dc.subjectFiltration
dc.subjectGeometry
dc.subjectLiquids
dc.titleContactless conductivity detector from printed circuit board for paper-based analytical systems
dc.typeArticle
dc.rights.holderScopus
dc.identifier.bibliograpycitationTalanta. Vol 206, (2020)
dc.identifier.doi10.1016/j.talanta.2019.120227
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.