Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/11853
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pungjunun K. | |
dc.contributor.author | Nantaphol S. | |
dc.contributor.author | Praphairaksit N. | |
dc.contributor.author | Siangproh W. | |
dc.contributor.author | Chaiyo S. | |
dc.contributor.author | Chailapakul O. | |
dc.date.accessioned | 2021-04-05T03:01:18Z | - |
dc.date.available | 2021-04-05T03:01:18Z | - |
dc.date.issued | 2020 | |
dc.identifier.issn | 9254005 | |
dc.identifier.other | 2-s2.0-85084572571 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/11853 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85084572571&doi=10.1016%2fj.snb.2020.128241&partnerID=40&md5=9c88c01b92e7727ab929a6ad5371e51e | |
dc.description.abstract | Due to similar properties in the electroanalysis of tin (Sn(II)) and lead (Pb(II)), the voltammograms of tin and lead overlap and it is difficult to simultaneously determine these two metals. Herein, we develop a simple fabricated sensor based on a bismuth nanoparticle-modified screen-printed graphene electrode (BiNP/SPGE) on a paper-based analytical device (PAD) for the simultaneous determination of Sn(II) and Pb(II) and combine it with a portable potentiostat. To overcome crossing interference, the use of hexadecyltrimethylammonium bromide (CTAB) can provide improved separation and enhanced sensitivity for Sn(II) and Pb(II) detection in oxalic acid as a supporting electrolyte while using square-wave anodic stripping voltammetry. Under optimal conditions, the linear range of both metals was determined to be 10–250 ng mL−1, and the calculated limit of detection (3SD/slope) was 0.26 ng mL−1 and 0.44 ng mL−1 for Sn(II) and Pb(II), respectively. This sensor was also applied to simultaneously determine Sn(II) and Pb(II) in canned food samples. The results obtained from the portable potentiostat were similar to the results obtained by a standard method. Therefore, the proposed device can be further improved for the realization of a rapid on-site detector for Sn(II) and Pb(II) detection in real samples. © 2020 Elsevier B.V. | |
dc.subject | Analytic equipment | |
dc.subject | Canning | |
dc.subject | Electrolytes | |
dc.subject | Graphite electrodes | |
dc.subject | Lead compounds | |
dc.subject | Oxalic acid | |
dc.subject | Voltage regulators | |
dc.subject | Voltammetry | |
dc.subject | Bismuth nanoparticles | |
dc.subject | Enhanced sensitivity | |
dc.subject | Hexadecyltrimethylammonium bromide | |
dc.subject | Paper-based analytical devices | |
dc.subject | Screen-printed graphene electrodes | |
dc.subject | Simultaneous determinations | |
dc.subject | Square wave anodic stripping voltammetry | |
dc.subject | Supporting electrolyte | |
dc.subject | Tin compounds | |
dc.title | Enhanced sensitivity and separation for simultaneous determination of tin and lead using paper-based sensors combined with a portable potentiostat | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | Sensors and Actuators, B: Chemical. Vol 318, (2020) | |
dc.identifier.doi | 10.1016/j.snb.2020.128241 | |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.