Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/11837
Full metadata record
DC FieldValueLanguage
dc.contributor.authorThangphatthanarungruang J.
dc.contributor.authorYakoh A.
dc.contributor.authorLaocharoensuk R.
dc.contributor.authorChotsuwan C.
dc.contributor.authorChailapakul O.
dc.contributor.authorSiangproh W.
dc.date.accessioned2021-04-05T03:01:16Z-
dc.date.available2021-04-05T03:01:16Z-
dc.date.issued2020
dc.identifier.issn15726657
dc.identifier.other2-s2.0-85086903570
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/11837-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85086903570&doi=10.1016%2fj.jelechem.2020.114361&partnerID=40&md5=b3eb0184195eaf50bb4d28bd1a072536
dc.description.abstractAn alternative approach for rapid, highly sensitive and specific analytical sensor for the simultaneous determination of fat-soluble vitamins (A, D, E and K) in different matric samples was demonstrated using our developed sensor by graphene nanocomposite. The adsorptive square wave voltammetry was used to determine the amounts of vitamin A, D, E and K in infant milk, yogurt and parsley. Various analytical conditions were investigated to enhance the best performance of the proposed method. Under optimal conditions, a good linear relationship was obtained between the anodic current and the concentration of vitamins within the range from 0.02 μg mL−1 to 1 μg mL−1. The limits of detection were found to be 0.0086, 0.0063, 0.0075 and 0.0071 μg mL−1 for vitamin A, D, E and K, respectively. The accuracy of the proposed sensor has been validated with the standard AOAC guideline. The reproducibility has also been demonstrated by repeating the experiments between sensor-to-sensor. Compared to conventional chromatographic methods, the electrochemical sensor outlined here shows a comparable performance yet faster, simpler, and cheaper approach that enables the continuous monitoring of the total quantity of vitamin A, D, E and K in various samples with good reliability, sensitivity, selectivity and accuracy. © 2020 Elsevier B.V.
dc.subjectChromatographic analysis
dc.subjectDairies
dc.subjectGraphene
dc.subjectNanocomposites
dc.subjectVitamins
dc.subjectVoltammetry
dc.subjectAnalytical conditions
dc.subjectChromatographic methods
dc.subjectContinuous monitoring
dc.subjectGraphene nanocomposites
dc.subjectLinear relationships
dc.subjectSimultaneous determinations
dc.subjectSimultaneous identification
dc.subjectSquare wave voltammetry
dc.subjectElectrochemical sensors
dc.titleHigh-efficient of graphene nanocomposite: Application to rapidly simultaneous identification and quantitation of fat-soluble vitamins in different matric samples
dc.typeArticle
dc.rights.holderScopus
dc.identifier.bibliograpycitationJournal of Electroanalytical Chemistry. Vol 873, (2020)
dc.identifier.doi10.1016/j.jelechem.2020.114361
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.