Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/11837
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Thangphatthanarungruang J. | |
dc.contributor.author | Yakoh A. | |
dc.contributor.author | Laocharoensuk R. | |
dc.contributor.author | Chotsuwan C. | |
dc.contributor.author | Chailapakul O. | |
dc.contributor.author | Siangproh W. | |
dc.date.accessioned | 2021-04-05T03:01:16Z | - |
dc.date.available | 2021-04-05T03:01:16Z | - |
dc.date.issued | 2020 | |
dc.identifier.issn | 15726657 | |
dc.identifier.other | 2-s2.0-85086903570 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/11837 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85086903570&doi=10.1016%2fj.jelechem.2020.114361&partnerID=40&md5=b3eb0184195eaf50bb4d28bd1a072536 | |
dc.description.abstract | An alternative approach for rapid, highly sensitive and specific analytical sensor for the simultaneous determination of fat-soluble vitamins (A, D, E and K) in different matric samples was demonstrated using our developed sensor by graphene nanocomposite. The adsorptive square wave voltammetry was used to determine the amounts of vitamin A, D, E and K in infant milk, yogurt and parsley. Various analytical conditions were investigated to enhance the best performance of the proposed method. Under optimal conditions, a good linear relationship was obtained between the anodic current and the concentration of vitamins within the range from 0.02 μg mL−1 to 1 μg mL−1. The limits of detection were found to be 0.0086, 0.0063, 0.0075 and 0.0071 μg mL−1 for vitamin A, D, E and K, respectively. The accuracy of the proposed sensor has been validated with the standard AOAC guideline. The reproducibility has also been demonstrated by repeating the experiments between sensor-to-sensor. Compared to conventional chromatographic methods, the electrochemical sensor outlined here shows a comparable performance yet faster, simpler, and cheaper approach that enables the continuous monitoring of the total quantity of vitamin A, D, E and K in various samples with good reliability, sensitivity, selectivity and accuracy. © 2020 Elsevier B.V. | |
dc.subject | Chromatographic analysis | |
dc.subject | Dairies | |
dc.subject | Graphene | |
dc.subject | Nanocomposites | |
dc.subject | Vitamins | |
dc.subject | Voltammetry | |
dc.subject | Analytical conditions | |
dc.subject | Chromatographic methods | |
dc.subject | Continuous monitoring | |
dc.subject | Graphene nanocomposites | |
dc.subject | Linear relationships | |
dc.subject | Simultaneous determinations | |
dc.subject | Simultaneous identification | |
dc.subject | Square wave voltammetry | |
dc.subject | Electrochemical sensors | |
dc.title | High-efficient of graphene nanocomposite: Application to rapidly simultaneous identification and quantitation of fat-soluble vitamins in different matric samples | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | Journal of Electroanalytical Chemistry. Vol 873, (2020) | |
dc.identifier.doi | 10.1016/j.jelechem.2020.114361 | |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.