Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/11800
ชื่อเรื่อง: Colorimetric detection of Cr3+ in dietary supplements using a smartphone based on EDTA and tannic acid-modified silver nanoparticles
ผู้แต่ง: Sangsin S.
Srivilai P.
Tongraung P.
Keywords: Absorption spectroscopy
Atomic absorption spectrometry
Colorimetry
Coordination reactions
Food additives
Metal nanoparticles
Nutrition
Red Shift
Silver nanoparticles
Smartphones
Vitamins
Calibration curves
Colorimetric detection
Coordinated complexes
Detection limits
Flame atomic absorption spectrometry
Positive coefficients
Silver nanoparticles (AgNps)
Stabilizing agents
Dietary supplements
วันที่เผยแพร่: 2021
บทคัดย่อ: A simplistic, portable and low-cost method for the rapid detection of Cr3+ was developed based on a smartphone readout and a co-functionalized silver nanoparticles (AgNPs) system for use as an on-site device in resource-poor areas. The presence of Cr3+ induced aggregation of AgNPs through coordinated complex formation between Cr3+ and stabilizing agents on the NPs surface, resulted in a bright yellow of an AgNPs solution turned to wine red along with a SPR band was red-shifted from 429 nm to 625 nm. A smartphone with an available free application, called “PhotoMetrix” was used to measure the RGB (red, green, blue) values of the color intensities in the AgNPs system and convert into Cr3+ concentration by using univariate calibration curves in less than 60s. This smartphone-based detection system showed a high selectivity of AgNPs with Cr3+ and gave a positive coefficient correlation (R2 = 0.9878) between the intensity of channel R and the Cr3+ concentration, with a linear range of 2.0–5.0 mg L−1, and a detection limit of 1.52 mg L−1. Furthermore, the proposed method has been successfully applied for quantification of Cr3+ in dietary supplement samples. The results obtained were in close agreement with those obtained in FAAS (Flame Atomic Absorption Spectrometry). The developed colorimetric system based on a smartphone readout device exhibits feasibility and reliability for on-site Cr3+ detection in the real samples. © 2020 Elsevier B.V.
URI: https://ir.swu.ac.th/jspui/handle/123456789/11800
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85092640225&doi=10.1016%2fj.saa.2020.119050&partnerID=40&md5=93ebb0823c1653a7aa9754f6709d0ff5
ISSN: 13861425
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.