dc.description.abstract Fiber-reinforced concrete (FRC) is a competitive solution for the durability of reinforced structures. This paper aims to observe the moment redistribution behavior occurring due to flexural and shear loading in Glass Fiber-Reinforced Polymer-(GFRP) reinforced continuous concrete beams. A rectangular cross-section was adopted in this study with dimensions of 200 mm in width and 300 mm in depth with a constant shear span-to-depth ratio of 3. The reinforcement ratio for the top and bottom were equal at sagging and hogging moment regions. A finite element model was created using Analysis System (ANSYS) and validated with the existing experimental results in the literature review. Based on the literature review, the parametric study was conducted on twelve beam specimens to evaluate the influence of concrete compressive strength, transversal GFRP stirrups ratio, and longitudinal reinforcement ratio on the redistribution of the moment in beams. Several codes and guidelines adopted different analytical models. The Canadian Standards Association (CSA) S806 adopted the modified compression field theory in predicting the shear capacity of the simply supported beams. Recently, various researchers encountered several factors and modifications to account for concrete contribution, longitudinal, and transverse reinforcement. A comparison between the predicting shear capacity of the generated finite element model, the analytical model, and the existing data from the literature was performed. The generated finite element model showed a good agreement with the experimental results, while the beam specimens failed in shear after undergoing significant moment redistribution from hogging to sagging moment region. The moment distribution observed about 21.5% from FEM of beam specimen GN-1.2-0.48-d, while the experimental results achieved 24% at failure load. For high strength concrete presented in beam specimen GH-1.2-0.63-d, the result showed about 20.2% moment distribution, compared to that achieved experimentally of 23% at failure load. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
dc.language en
dc.subject Analytical models
dc.subject Bridge decks
dc.subject Compressive strength
dc.subject Concrete beams and girders
dc.subject Glass fibers
dc.subject High performance concrete
dc.subject Reinforced concrete
dc.subject Concrete beam
dc.subject Continuous beams
dc.subject Finite element modelling (FEM)
dc.subject Glassfiber reinforced polymers (GFRP)
dc.subject Moment redistribu-tion
dc.subject Moment redistribution
dc.subject Reinforcement ratios
dc.subject Sagging moment
dc.subject Shear capacity
dc.subject Stirrup
dc.subject Finite element method
dc.title Finite element analysis of glass fiber-reinforced polymer-(Gfrp) reinforced continuous concrete beams
dc.type Article
dc.rights.holder Scopus
dc.identifier.bibliograpycitation Polymers. Vol 13, No.24 (2021)
dc.identifier.doi 10.3390/polym13244468


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics