DSpace Repository

Pulsed amperometry for anti-fouling of boron-doped diamond in electroanalysis of β-agonists: Application to flow injection for pharmaceutical analysis

Show simple item record

dc.contributor.author Karuwan C.
dc.contributor.author Mantim T.
dc.contributor.author Chaisuwan P.
dc.contributor.author Wilairat P.
dc.contributor.author Grudpan K.
dc.contributor.author Jittangprasert P.
dc.contributor.author Einaga Y.
dc.contributor.author Chailapakul O.
dc.contributor.author Suntornsuk L.
dc.contributor.author Anurukvorakun O.
dc.contributor.author Nacapricha D.
dc.date.accessioned 2021-04-05T04:32:26Z
dc.date.available 2021-04-05T04:32:26Z
dc.date.issued 2006
dc.identifier.issn 14243210
dc.identifier.other 2-s2.0-33947367459
dc.identifier.uri https://ir.swu.ac.th/jspui/handle/123456789/15060
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-33947367459&doi=10.3390%2fs6121837&partnerID=40&md5=482d3a4febd812dc93ccff22e3ae48dc
dc.description.abstract This work presents the construction and application of boron-doped diamond (BDD) thin film electrode as sensor for the determination of three β-agonists, viz. salbutamol, terbutaline and clenbuterol. Although well-known as a chemically inert material, BDD film however shows fouling in detection of these compounds using fixed-potential mode amperometry. A suitable waveform for pulsed amperometric detection (PAD) was developed and used to determine the agonist compounds. It was seen that the developed PAD significantly refreshed the BDD surface for long-term detection in flow injection analysis. Linear working ranges were 0.5-100 μM, 1.0-100 μM and 0.5-50 μM for salbutamol, terbutaline and clenbuterol, respectively. The developed PAD-BDD system was applied to successfully determine salbutamol and terbutaline in commercial pharmaceutical products. The methods were validated with a capillary electrophoresis method. © 2006 by MDPI.
dc.subject Capillary electrophoresis
dc.subject Diamonds
dc.subject Boron doped diamond
dc.subject Flow injection
dc.subject Flow injection analysis
dc.subject Pharmaceutical analysis
dc.subject Pharmaceutical products
dc.subject Pulsed amperometric detection
dc.subject Pulsed amperometry
dc.subject Thin-film electrode
dc.subject Boolean functions
dc.title Pulsed amperometry for anti-fouling of boron-doped diamond in electroanalysis of β-agonists: Application to flow injection for pharmaceutical analysis
dc.type Article
dc.rights.holder Scopus
dc.identifier.bibliograpycitation Sensors. Vol 6, No.12 (2006), p.1837-1850
dc.identifier.doi 10.3390/s6121837


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics