DSpace Repository

Repeatability in column preparation of a reversed-phase C18 monolith and its application to separation of tocopherol homologues

Show simple item record

dc.contributor.author Kositarat S.
dc.contributor.author Smith N.W.
dc.contributor.author Nacapricha D.
dc.contributor.author Wilairat P.
dc.contributor.author Chaisuwan P.
dc.date.accessioned 2021-04-05T03:35:14Z
dc.date.available 2021-04-05T03:35:14Z
dc.date.issued 2011
dc.identifier.issn 399140
dc.identifier.other 2-s2.0-79958106019
dc.identifier.uri https://ir.swu.ac.th/jspui/handle/123456789/14509
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-79958106019&doi=10.1016%2fj.talanta.2011.03.083&partnerID=40&md5=1d593ea0e8d9777fdfa69ba4450a9110
dc.description.abstract This work investigated the repeatability of column preparation for a reversed-phase C18 monolith, namely stearyl methacrylate-co-ethylene glycol dimethacrylate (SMA-EDMA). The columns were thermally polymerised using three commonly available heating devices (GC oven, hot air oven and water bath) and their chromatographic performance evaluated using micro-liquid chromatography for separation of five test compounds. Precision in terms of %RSD of retention times were 9.0, 6.5, and 12.5 using GC oven, hot air oven and water bath, respectively. Between-batch precision for the hot air oven (n = 3 days) was less than 10.4% for retention time. The SMA-EDMA monolith was applied to the separation of tocopherol homologues by capillary electrochromatography. Usually tocopherol homologues cannot be completely separated by conventional reversed-phase C8- or C18-packed bed or C18-silica based monolithic columns. Polymer monolith has been shown to give remarkable selectivity towards the tocopherols compared to the conventional microparticulate phase and silica based monolith. Successful separation of the tocopherol isomers was achieved on the SMA-EDMA monolith without any column modification. © 2011 Elsevier B.V. All rights reserved.
dc.subject Ethylene
dc.subject Ethylene glycol
dc.subject Isomers
dc.subject Liquid chromatography
dc.subject Ovens
dc.subject Packed beds
dc.subject Polymers
dc.subject Silica
dc.subject Capillary electrochromatography
dc.subject Chromatographic performance
dc.subject Ethylene glycol dimethacrylate
dc.subject Micro-liquid chromatography
dc.subject Polymer based
dc.subject Repeatability study
dc.subject Stearyl methacrylate
dc.subject Tocopherols
dc.subject Separation
dc.title Repeatability in column preparation of a reversed-phase C18 monolith and its application to separation of tocopherol homologues
dc.type Conference Paper
dc.rights.holder Scopus
dc.identifier.bibliograpycitation Talanta. Vol 84, No.5 (2011), p.1374-1378
dc.identifier.doi 10.1016/j.talanta.2011.03.083


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics