dc.description.abstract An experimental investigation on the thermal cooling of vapor chamber for cooling computer processing unit of the personal computer is performed. Two different configurations of the vapor chambers with de-ionized water as working fluid are tested under the real operating conditions of PCs. Parametric studies including different aspect ratios, fill ratios, and operating conditions of PC on the CPU temperature are considered. It was found that the vapor chamber cooling technique has significant effect on the thermal cooling of CPU. Average CPU temperatures obtained from the vapor chamber cooling system are 4.1%, 6.89% lower than those from the conventional cooling system for no load and 90% operating loads, respectively. In additional, this cooling system requires 6.89%, 10.53% lower energy consumption for no load and 90% operating loads, respectively. The results of this study are of technological importance for the efficient design of cooling systems of the personal computers or electronic devices to enhance cooling performance. © 2012 Elsevier Ltd.
dc.subject Computer processing
dc.subject Cooling performance
dc.subject Cooling technique
dc.subject Efficient designs
dc.subject Electronic device
dc.subject Electronics cooling
dc.subject Experimental investigations
dc.subject No load
dc.subject Operating condition
dc.subject Operating loads
dc.subject Parametric study
dc.subject Real operating conditions
dc.subject Thermal cooling
dc.subject Vapor chamber
dc.subject Working fluid
dc.subject Aspect ratio
dc.subject Cooling systems
dc.subject Energy utilization
dc.subject Personal computers
dc.subject Program processors
dc.subject Thermoelectric equipment
dc.subject Water vapor
dc.subject Electronic cooling
dc.title On the thermal cooling of central processing unit of the PCs with vapor chamber
dc.type Article
dc.rights.holder Scopus
dc.identifier.bibliograpycitation International Communications in Heat and Mass Transfer. Vol 39, No.8 (2012), p.1165-1168
dc.identifier.doi 10.1016/j.icheatmasstransfer.2012.07.013


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics