DSpace Repository

Energy savings analysis and harmonics reduction for the electronic ballast of T5 fluorescent lamp in a building's lighting system

Show simple item record

dc.contributor.author Chiradeja P.
dc.contributor.author Ngaopitakkul A.
dc.contributor.author Jettanasen C.
dc.date.accessioned 2021-04-05T03:25:44Z
dc.date.available 2021-04-05T03:25:44Z
dc.date.issued 2015
dc.identifier.issn 3787788
dc.identifier.other 2-s2.0-84927718027
dc.identifier.uri https://ir.swu.ac.th/jspui/handle/123456789/13689
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-84927718027&doi=10.1016%2fj.enbuild.2015.03.042&partnerID=40&md5=a295f1fdc9f747c1726b9c422256b594
dc.description.abstract Lighting is one of the major energy end uses, which accounts for approximately 20-30% of electricity consumption in buildings. In fact, the fluorescent lamp is the most employed lamp in a lighting system for both inside and outside the building. The ballast is one of the major components of fluorescent lamps; it exists commercially as an electromagnetic ballast, a low loss ballast and an electronic ballast. To reduce energy consumption in a lighting system, the electronic ballast has already been introduced for profit in terms of its peak demand reduction and energy conservation in the building. However, when the electronic ballast functions, harmonics will be generated. Hence, this paper investigates energy savings and the generation of harmonics when using a fluorescent T5 lamp with electronic ballast in a building. The efficiency indices in terms of illumination, energy savings, and harmonics are also evaluated and compared with the fluorescent T8 lamp operating with a low watt loss electromagnetic ballast, which is also widely used. The obtained results are useful for the design and decision to install a fluorescent T5 lamp with electronic ballast in building lighting system to conserve energy and/or reduce energy consumption for the future of the country. © 2015 Published by Elsevier B.V.
dc.subject Ballasts (lamp)
dc.subject Buildings
dc.subject Energy utilization
dc.subject Fluorescence
dc.subject Fluorescent lamps
dc.subject Harmonic analysis
dc.subject Historic preservation
dc.subject Lighting
dc.subject Lighting fixtures
dc.subject Electricity-consumption
dc.subject Electromagnetic ballasts
dc.subject Electronic ballasts
dc.subject Generation of harmonics
dc.subject Harmonics
dc.subject Harmonics reduction
dc.subject Lighting systems
dc.subject Reduce energy consumption
dc.subject Energy conservation
dc.title Energy savings analysis and harmonics reduction for the electronic ballast of T5 fluorescent lamp in a building's lighting system
dc.type Article
dc.rights.holder Scopus
dc.identifier.bibliograpycitation Energy and Buildings. Vol 97, (2015), p.107-117
dc.identifier.doi 10.1016/j.enbuild.2015.03.042


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record