DSpace Repository

A "dual-acceptor channel" membraneless gas-diffusion unit for simultaneous determination of ethanol and acetaldehyde in liquors using reverse flow injection

Show simple item record

dc.contributor.author Choengchan N.
dc.contributor.author Poontong B.
dc.contributor.author Mathaweesansurn A.
dc.contributor.author Maneerat N.
dc.contributor.author Motomizu S.
dc.contributor.author Ratanawimarnwong N.
dc.contributor.author Nacapricha D.
dc.date.accessioned 2021-04-05T03:21:46Z
dc.date.available 2021-04-05T03:21:46Z
dc.date.issued 2018
dc.identifier.issn 9106340
dc.identifier.other 2-s2.0-85041825200
dc.identifier.uri https://ir.swu.ac.th/jspui/handle/123456789/12896
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041825200&doi=10.2116%2fanalsci.34.169&partnerID=40&md5=8f2296c566a063d22b5ff6dec3370175
dc.description.abstract A new design of membraneless gas-diffusion unit with dual acceptor channels for separation, collection and simultaneous determination of two volatile analytes in liquid sample is presented. The unit is comprised of three parallel channels in a closed module. A sample is aspirated into the central channel and two kinds of reagents are introduced into the other two channels. Two analytes are isolated from the sample matrix by diffusion into head-space and absorbed into the specific reagents. Non-absorbed vapor is released by opening the programmable controlled lid. The unit was applied to liquors for measurement of ethanol and acetaldehyde using reverse flow injection. Dichromate and nitroprusside were exploited as reagents for colorimetric detection of ethanol and acetaldehyde, respectively. Good linearity ranges (r2 > 0.99) with high precision (RSD < 2%) and high accuracy (recovery: 90 - 105%) were achieved. The results were compared to the results by GC-FID and no significant difference was observed by paired t-test (95% confidence). © The Japan Society for Analytical Chemistry.
dc.subject Acetaldehyde
dc.subject Chromates
dc.subject Diffusion in gases
dc.subject Dual-acceptor channel
dc.subject Gas-diffusion unit
dc.subject Liquor
dc.subject Reverse flow
dc.subject Simultaneous determinations
dc.subject Ethanol
dc.title A "dual-acceptor channel" membraneless gas-diffusion unit for simultaneous determination of ethanol and acetaldehyde in liquors using reverse flow injection
dc.type Article
dc.rights.holder Scopus
dc.identifier.bibliograpycitation Analytical Sciences. Vol 34, No.2 (2018), p.169-175
dc.identifier.doi 10.2116/analsci.34.169


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record