dc.description.abstract Electrical Impedance Tomography (EIT) is an imaging technique which relies on the accuracy of boundary voltage measurement. In application to the head of EIT, the scalp voltage is very small and sensitive to noise and error. Electrode placement error is an error which is difficult to avoid in practice. Furthermore, the exact value of electrode contact impedance is difficult to know. In this study, the influence of electrode placement error and inaccurate electrode contact impedance were investigated by simulation. The result shows that the scalp voltage error due to the placement error was between 0.003 mV and 4.670 mV. Comparing to the scalp voltage response obtained from brain stimulation, which has been reported less than 90 μV, the most of the error values were much larger. The voltage errors due to inaccurate contact impedance were less than 1.2 μV which is very small and ignorable. This indicates the importance of the attachment procedure of electrodes that needs to be very careful. © 2019 IEEE.
dc.subject Electric contacts
dc.subject Electric impedance
dc.subject Electric impedance measurement
dc.subject Electric impedance tomography
dc.subject Electrodes
dc.subject Brain stimulation
dc.subject Contact impedance
dc.subject Electrical impe dance tomography (EIT)
dc.subject Electrical impedance tomography
dc.subject Electrode contacts
dc.subject Electrode placement
dc.subject Voltage error
dc.subject Voltage response
dc.subject Errors
dc.title Influence of electrode placement error and contact impedance error to scalp voltage in electrical impedance tomography application
dc.type Conference Paper
dc.rights.holder Scopus
dc.identifier.bibliograpycitation iEECON 2019 - 7th International Electrical Engineering Congress, Proceedings. (2019)
dc.identifier.doi 10.1109/iEECON45304.2019.8939016


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics